The problem: chemical data that nobody keeps current
Chemical management usually starts with good intentions and a spreadsheet. Over time the inventory drifts from reality. Safety data sheets are filed as PDFs that nobody opens, and some are years out of date. Exposure measurements live in a consultant's report. COSHH assessments are written once and never reviewed. When an inspector asks which chemicals are stored in a particular store, or whether an oxidizer sits next to a flammable solvent, the answer takes days.
What good chemical management looks like
- One inventory, where every chemical is stored in a known, registered location.
- A current safety data sheet (SDS) for every product, with its review date tracked.
- GHS classification, pictograms and hazard statements recorded for each chemical.
- Exposure monitoring compared with occupational exposure limits (OELs).
- A risk assessment for each hazardous substance, with controls chosen using the hierarchy of controls.
- Segregation checks, so incompatible chemicals are not stored together.
How SafetyPro organises chemical management
The Chemicals and SDS module has ten tabs: Chemical Inventory, Storage Areas, SDS Library, GHS Classification, Exposure Limits, COSHH Assessments, Risk Controls, Radioactive Materials, Explosives and Energetics, and Analytics. Each record belongs to a project, and each action is controlled by permissions, so a user who can view chemicals cannot necessarily edit or delete them.
Each chemical in the inventory carries its name, CAS number, formula, supplier, quantity and unit, physical state, risk level, signal word (Danger or Warning), H-codes, P-codes, GHS pictograms, and SDS revision and expiry dates.
Storage areas as a register, not free text
A common weakness is the storage location typed as free text, such as Store 2, store-2 or the shed. In SafetyPro, storage areas are registered once, and a chemical's location can only be chosen from that register. The database enforces this. A chemical cannot be saved without an area, the area must belong to the same project and be active, area names are unique within a project, and an area that still holds chemicals cannot be deleted.
Each storage area records its type (for example a flammables cabinet, corrosives cabinet or gas cylinder cage), ventilation and air changes per hour, cooling and temperature range, fire detection and suppression, the electrical hazardous area class (Zone 1 or Zone 2), containment and bund capacity, eyewash and safety shower, security, signage, and the last and next inspection dates. An area can also list the GHS classes it permits or prohibits. If you place a chemical whose pictograms conflict with those lists, the platform warns you to check segregation. It is a warning, not a block, so the decision stays with a competent person.
AI that reads the safety data sheet for you
Typing an SDS into a system is slow and error-prone. In SafetyPro, a user can upload an SDS as a PDF of up to 8 MB. AI reads the document, usually in 15 to 30 seconds, and returns structured data: chemical identity, GHS pictograms, signal word, H-codes and P-codes, exposure limits, PPE, engineering controls, storage requirements, spill response, fire-fighting measures, first aid, and a summary of each of the 16 SDS sections.
Nothing is saved straight away. The extracted data opens in a review screen where every field can be corrected. Only when the user confirms does the platform create the chemical and its SDS library record, together with linked records where the data supports them: an exposure limits record when an OEL or STEL was found, a controls record when PPE, spill or fire measures were found, and, for hazardous chemicals, a COSHH assessment that starts as a Draft for a person to complete and approve.
Many Gulf sites have multilingual workforces. An SDS can be translated by AI into any of 24 supported languages, including Arabic, Urdu, Hindi, Bengali, Nepali, Tagalog and Tamil. The translation is saved on the chemical record and marked as AI-translated with its date.
GHS classification and SDS status
The GHS tab shows the nine GHS pictograms, from GHS01 Exploding Bomb to GHS09 Environment, with reference tables of hazard (H) and precautionary (P) statements and a classification summary across the inventory. Each chemical also has an SDS status: No SDS, Current, Expiring Soon (within 30 days of the SDS expiry date) or Expired. The Analytics tab shows an Upcoming Reviews timeline that lists upcoming and overdue SDS expiry dates and COSHH review dates together.
Exposure monitoring against limits
Exposure records hold the OEL (8-hour TWA), STEL (15 minutes), ceiling and PEL, in ppm, mg/m3, f/cc or ug/m3, with the limit source (ACGIH, OSHA, NIOSH, EU-OEL, HSE-UK or a local limit). Each measurement records the sampling type, duration, date, location, the worker or team, method, equipment, ventilation and whether respiratory protection was worn. A record is marked Exceeded when the measured value is above the OEL, and Approaching when it is above 80 percent of it. When a value entered on the form is above the ceiling limit, the form shows a stop-work alert.
A built-in calculator works out the time-weighted average from up to four exposure periods, for 8, 10 or 12-hour shifts:
TWA = (C1 x T1 + C2 x T2 + C3 x T3 + C4 x T4) / shift hours
Exposure monitoring data is sent only to users with chemicals view permission, or with edit rights on those records.
COSHH assessments and the hierarchy of controls
A COSHH assessment records the substance, hazards, who is at risk (including young workers and pregnant workers), existing controls, exposure level, additional controls required, assessor, and assessment and review dates. Risk is scored on a 5 by 5 matrix of likelihood (Rare to Almost Certain) and severity (Negligible to Catastrophic), with scores of 15 and above shown in red.
Risk controls are recorded by type, following the hierarchy of controls: Elimination, Substitution, Engineering, Administrative and PPE, each with an effectiveness rating and spill, exposure, fire and emergency procedures.
Storage compatibility checks, with and without AI
With two or more chemicals in the inventory, a compatibility check reviews every pair. A rule-based check runs first and always gives a result. It flags acids with bases, oxidizers with flammables, oxidizers with acids, flammables with explosives, water-reactive materials with aqueous chemicals, and cyanides, sulfides or azides with acids. AI then adds a deeper review with storage groups and segregation issues based on current locations. If the AI is unavailable, the rule-based findings are still shown. The result can be exported as a PDF report, which states that it supports HSE review and does not replace the SDS or a competent professional.
Other AI assistants in the module suggest GHS classification from a chemical name, draft a COSHH assessment, propose exposure limits, prepare an emergency response guide for a chemical, scan the inventory for risks, predict exposure trends from at least two records, and propose missing controls. Proposed controls are saved only when a user ticks them. Treat every AI output as a suggestion that a competent person reviews.
For sites that hold them, the module keeps separate registers for radioactive sources, dose records and radioactive transport certificates, and for explosives inventory, shot logs and explosives transport records. Each has its own permissions.
A practical rollout plan
- Register your storage areas first, with their fire, ventilation and containment details and any prohibited GHS classes.
- Upload the SDS for your highest-risk chemicals and review each extraction carefully before saving.
- Complete the draft COSHH assessments the SDS import creates, and set review dates.
- Enter exposure limits and start recording monitoring results for the substances people are most exposed to.
- Run the compatibility check, act on the findings, and repeat it whenever new chemicals arrive.
- Use the Upcoming Reviews timeline in Analytics each month to renew expiring SDS and overdue COSHH reviews.