Why heat stress needs a number, not a feeling
Air temperature alone does not describe heat stress. Humidity, wind and direct sun change how fast the body can cool down. The Wet Bulb Globe Temperature (WBGT) combines these factors into one value, and it is widely used, for example in ISO 7243, to decide work/rest cycles.
On many sites, WBGT is read by hand a few times a day, written on a board and never stored. When an incident happens, nobody can show what the conditions were or what was done about them.
How SafetyPro calculates WBGT for your sites
In the WBGT Monitor, you add your site locations with their coordinates. For each site, SafetyPro fetches current weather data from the Open-Meteo service: air temperature, relative humidity, wind speed and direct solar radiation. It then estimates the natural wet bulb temperature and the globe temperature, and combines them with the outdoor WBGT formula:
WBGT = 0.7 x Tw + 0.2 x Tg + 0.1 x Ta
Here Tw is the natural wet bulb temperature, Tg the globe temperature and Ta the air temperature. Each site card shows the WBGT value and its inputs, and an hourly forecast chart shows how WBGT is expected to change during the day. While the page is open, the data refreshes every 5 minutes.
Clear risk bands and work/rest cycles
Every WBGT value is placed in one of six risk bands:
- Minimal: below 20 °C
- Low: 20 to 25 °C
- Moderate: 25 to 28 °C
- High: 28 to 30 °C
- Very High: 30 to 33 °C
- Extreme: 33 °C and above
The band is then combined with the work category, Light, Moderate or Heavy, to give an allowable work/rest cycle and an action: Continue, Modify or Stop. For example, at a WBGT of 30 to 33 °C, moderate work is set to 30 minutes of work and 30 minutes of rest, and heavy work to 15 minutes of work and 45 minutes of rest. At 33 °C and above, moderate and heavy outdoor work should stop. The same table is used for manual entries and automatic readings, so both describe conditions the same way.
Automatic capture into the heat stress register
In Occupational Health, each project can switch on WBGT auto-capture. The settings are simple:
- Mode: Manual only, Auto only, or Manual + Auto. Manual entry always stays available.
- Site: which WBGT Monitor location to read.
- Interval: every 15 or 30 minutes, or every 1, 2 or 4 hours.
- Default work category: used to calculate the allowable duration on automatic rows.
- Fallback if the data is unavailable: skip the capture, repeat the last known reading and mark it stale, or show an alert and skip.
Each automatic row is saved with its time, its source and the full weather context: temperature, humidity, wind, solar radiation, wet bulb and globe temperature. Rows are clearly marked as automatic, so they can be told apart from manual readings. When a captured value reaches 30 °C a warning is shown, and at 32 °C an urgent stop-work warning is shown.
Honest limits
- The value is an estimate calculated from weather data for the site coordinates. It is not a measurement taken on your site, and it does not replace a calibrated WBGT meter where your procedures or regulations require one.
- Local conditions, such as work next to hot equipment, inside enclosures or on reflective surfaces, can be hotter than the weather data suggests.
- Auto-capture runs in the browser. It records readings only while the platform is open and auto-capture is running for a user who is allowed to add readings. Days without an active session may have no automatic readings, and the register says so.
- Auto-capture is off by default. A user with the right permission must enable it for each project.
Getting started
- Add each work location to the WBGT Monitor with accurate coordinates.
- Check the hourly forecast every morning and plan heavy outdoor tasks for the cooler hours.
- Switch on auto-capture for each project, choose the site and an interval, and set the default work category to match the main type of work.
- Keep taking manual readings with a meter at high-risk locations, and record them in the same register.
- Review the register with supervisors so that work/rest cycles are actually applied.